1544174 - Mouse over text for charts is truncated after < symbol.

SAP Knowledge Base Article - Public

1544174 - Mouse over text for charts is truncated after < symbol.

Symptom

When the Mouse-Over text contains < symbol for the Series Name/Axis Labels, Xcelsius truncates the remaining text that’s after the < symbol.

Environment

Xcelsius 2008 Service Pack 3

Reproducing the Issue

1.  Create a dashboard with a Chart component.

2.  Go to Properties Window.

3.  Under General tab check By Series and add a new Series.

4.  Give name to the series which contains < character (eg: ‘<SampleName’).

5.  Preview the dashboard.

6.  Move mouse over the bars of the Chart component.

7.  Notice that the Mouse over text gets truncated.

Cause

This issue has been identified and logged under Problem Report ID: ADAPT01369545/ADAPT01388980.

Resolution

This issue has been resolved in Xcelsius Service Pack 3 Fix Pack 3.2.

Keywords

Xcelsius, Phase, Theme, Missing , KBA , BI-RA-XL , Dashboards and Presentation Design , Problem

Product

SAP BusinessObjects Xcelsius Enterprise 2008