SAP Knowledge Base Article - Preview

2857906 - Signal 11 in imrs_abort_to_im() when DML on an ODMVCC enabled table is rolled back after Error 728 - SAP ASE

Symptom

  • A connection is terminated with an "infected with signal 11" error in the module imrs_abort_to_im():

Current process (0x8d3046a) infected with signal 11 (SIGSEGV)
Address 0x0x0000000000e607f1 (imrs_abort_to_imrv+0x241), siginfo (code, address) = (1, 0x0x00000000000134c4)

  • This error is followed by a stack trace which includes modules:

imrs_abort_to_imrv
xact__rollbackxact
xact__rollback_local
xact_rollback
le_runerr
s_xoltp_dml

  Note: A complete stack trace is available under Attachments.

  • The stack trace shows that the last error hit by the terminated process was Error 738 (lasterror = 728):

Error: 728, Severity: 17, State: 5
Allocation of size 160 bytes from the row storage cache, 'my_odmvcc', failed as there is not enough memory available in the cache. Please increase the cache size. Memory allocator information = 0x0.



Environment

SAP Adaptive Server Enterprise (ASE) 16.0

Product

SAP Adaptive Server Enterprise 16.0

Keywords

CR813895, CR#813895, 813895, On-Disk-MVCC, DML, IMRS , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.