2769883 - dataserver incorrectly calculates total logical memory at startup

Symptom

  • dataserver incorrectly calculates total logical memory at startup after upgrading from 16 SP02 PL06 HF1 to 16 SP03 PL05.
  • Whenever restarting the ASE server, it's logged below messages and can't be upgraded.

    00:0000:00000:00000:2019/03/17 18:14:59.00 kernel Using config area from primary master device.
    00:0000:00000:00000:2019/03/17 18:14:59.00 server The value of the 'max memory' parameter (131920896) defined in the configuration file is not high enough to set the other parameter values specified in the configuration file. 'max memory' should be greater than the 'total logical memory' '117771'.

Read more...

Environment

  • SAP Adaptive Server Enterprise (ASE) 16 SP03 PL05

Product

SAP Adaptive Server Enterprise 15.7

Keywords

CR#818805, CR818805, CR 818805, 818805, TF5801, traceflag 5801, -T5801 , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Problem