SAP Knowledge Base Article - Preview

2723934 - Non-Fatal error 's_barray.cxx:11884' happened on FP variable page of a column -- SAP IQ16.1

Symptom

Customer upgraded IQ version to 16.1 SP02.12  from 16.1 SP02.10  in order to apply the fix of CR 814650 on 2018-11-20.  It happened while inserting  data  into existing table. But sp_iqcheckdb 'verify table' report 'No Errors Detected'. It seems the  s_barray error is detected when new modification is applied, rather than being existing inconsistency.

  **.iqmsg :
 
       I. 11/20 13:57:42. 0000002149 Page Header:
       ...
       I. 11/20 13:57:42. 0000002149 VariablePageHeader:
       ...
       I. 11/20 13:57:45. 0000002149     **       Non-Fatal IQ Internal Error Detected
       I. 11/20 13:57:45. 0000002149     **       at slib/s_barray.cxx:11883  on thread 333335 (TID 1296)
    
  ** stacktrace :
       ===== Thread Number  ....
       .. pcstkwalk
       .. ucstkgentrace
       .. StackTraceForThisThread
       .. hs_idxexception::hs_idxexception
       .. hs_ThrowIdxException
       .. s_mergeFINALWriter::CompletePage
       .. s_mergeFINALWriter::WriteLHSBlockVarConstant
       .. s_mergeFINALWriter::DoInsert
       .. hs_dpInsert::Insert


Read more...

Environment

SAP IQ16.1

Product

SAP IQ 16.1

Keywords

"s_barray.cxx" ; CR817478;CR 817478;817478; 814650 ;  'variable-length FP' ; , KBA , BC-SYB-IQ , Sybase IQ , Problem

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.