SAP Knowledge Base Article - Preview

2693399 - Operating system call WSASend failed error no. 10053 with SMDAGENT_<SID> user

Symptom

Operating system call WSASend failed (error no. 10053)

This error logged in SM21 log periodically with user SMDAGENT_<SID>.

*Note*

SMDAGENT_<SID> user is the key point to check whether this KBA is the case or not.

For other users, it may be caused by other reasons.

 

Error in the corresponding dev_w50 trace:

M  ***LOG Q0I=> NiIWrite: P=127.0.0.1:3300; L=127.0.0.1:<port>: WSASend (10053: WSAECONNABORTED: Software caused connection abort) [nixxi.cpp 4615]

M  *** ERROR => NiIWrite: SiSendV failed for hdl 16/sock 2036

If you raise trace level 2, you can see gateway closed the connection due to idle monitoring timeout in dev_rd trace:

GwICheckMonitor: check idle monitor connections (timeout 300 secs)

GwICheckMonitor: monitor connection closed (idle for 317 secs)

GwFreeHdlInfoMemory: free 0000000008E173D0 (data)

GwSelClear: clear RWC for hdl 167

NiICloseHandle: shutdown and close hdl 167/sock 2004


Read more...

Environment

SAP system with kernel 72x or 74x, environment which has solman systems installed.

Keywords

SMDAGENT, 10053, gateway, idle time out , KBA , BC-CST-GW , Gateway/CPIC , Problem