2537239 - IBM i : Signal 6 encountered: sapgenuuid() | SAP Knowledge Base Article

SAP Knowledge Base Articles - preview

2537239 - IBM i : Signal 6 encountered: sapgenuuid()


The SAP system starts, but all work processes end very quickly. In the logs, you can find Signal 6 errors.
These errors can occur in the work process trace files (dev_WXX) and has also been observed in the gateway trace, dev_rd.

Signal 6 encountered.

=> 64 bit R/3 Kernel
=> 64 bit OS400 Kernel
=> Heap limit      = unlimited
=> Stack limit     = unlimited
=> Core limit      = 16777216
=> File size limit = unlimited
=> Heap address  = 0x800000000000000000008016B0E19660
=> Stack address = 0xfffffffffffd840
=> Stack low     =  0xfffffffffffbf70
=> Stack high    =  0xffffffffffff630
=> Stack Trace:
 Unknown at 0x3618
 _p_raise() at 0x9000000006ccac8
 raise() at 0x900000000039acc
 abort() at 0x900000000055748
 myabort__3stdFv() at 0x900000000730ff0
 terminate__3stdFv() at 0x900000000730ecc
 terminate__Fv() at 0x9000000007318f0
 Unknown at 0x900000000732a34
 sapgenuuid() at 0x1000de4cc
 pfget_uuid() at 0x10065c818
 pfcreate_sap_uuid_force() at 0x10065c2bc
 GwInitReader__FiPPc() at 0x1000022c0
 main() at 0x100000908



SAP on IBM i


KBA , BC-OP-AS4 , IBM AS/400 , BC-DB-DB4 , DB2 for AS/400 , Problem

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.