SAP Knowledge Base Article - Preview

2370773 - During the Managed System Configuration, the DBA cockpit connection of HANA ends with the error: Database connection ADBC error 'internal error 16 has occurred'

Symptom

During the Managed System Configuration, in the step ‘Enter System Parameter’, the following message appears when the DBA Cockpit connection is configured:

The connection <SID> is not set up correctly.

Database connection ADBC error 'internal error 16 has occurred'

DBAcockpit Issue.PNG

The following message can be found in the database trace (how to get the database trace in the Resolution topic of this note):

B  Loading DB library 'I:\usr\sap\<SID>\<Instance>\exe\dbhdbslib.dll' ...
M  *** ERROR => DlLoadLib()==DLENOACCESS - LoadLibrary("I:\usr\sap\<SID>\<Instance>\exe\dbhdbslib.dll")
  Error 126 = "The specified module could not be found." [dlnt.c       255]
M  {root-id=3C4A926CD1E61ED6A094B048742B7B73}_{conn-id=00000000000000000000000000000000}_0

B  *** ERROR => Couldn't load library 'I:\usr\sap\<SID>\<Instance>\exe\dbhdbslib.dll'
 [dbcon.c      5973]
B  {root-id=3C4A926CD1E61ED6A094B048742B7B73}_{conn-id=00000000000000000000000000000000}_0


Read more...

Environment

  • SAP Solution Manager 7.1

Product

SAP Solution Manager 7.1

Keywords

DlLoadLib, DLENOACCESS, LoadLibrary, dbcon, dbhdbslib, dbhdbslib.dll , KBA , HAN-DB-CLI , SAP HANA Clients (JDBC, ODBC) , SV-SMG-INS-DIA , Configuration of Root Cause Analysis related infrastructure , Problem

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required).

Search for additional results