2114240 - Issues WIth Longptr Assertion Failure - SAP PB

Symptom

  • Application migrated from PB 12.5.2 to 12.6 with the following line of code in an inherited PictureButton Other event:

Mod(lparam, 256)

Compilation results in the following assertion failure:

---------------------------

Assertion Failure

---------------------------

Invalid type in cm_intrinsic_mod,

file cmintrin.cpp, line 2264

  • In PB 12.6, the parameters passed to the Other event have changed from Long to Longptr.   According to the PB 12.6 docs, the Longptr is the same as Long although there is a note that doing complex operations on longptr datatypes may not work. 

Read more...

Environment

SAP PowerBuilder 12.6

Product

SAP PowerBuilder 12.5 ; SAP PowerBuilder 12.6

Keywords

PowerBuilder, Power Builder, CR 776509, CR776509 , KBA , BC-SYB-PB , Powerbuilder , Bug Filed