Symptom

  • The ASE datatype TINYINT should only permit values from 0 to 255 inclusive
  • INSERT of values outside that range will result in a failure with ASE error 247:

    Msg 247, Level 16, State 1: Line 1:
    Arithmetic overflow during implicit conversion of INT value '-33' to a TINYINT field.

  • SELECT of the negative of a TINYINT value should return error 247, but returns incorrect value without an error instead:


Read more...

Environment

SAP Adaptive Server Enterprise (ASE) all versions

Product

SAP Adaptive Server Enterprise 15.7 ; SAP Adaptive Server Enterprise 16.0 ; Sybase Adaptive Server Enterprise 12.5 ; Sybase Adaptive Server Enterprise 15.0 ; Sybase Adaptive Server Enterprise 15.5

Keywords

negative, TINYINT , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-SYB-ASE-CE , ASE Cluster Edition (Standalone) , Bug Filed

About this page