SAP Knowledge Base Article - Preview

2084785 - A process is infected with signal 11 in close_range__fdpr() with stack trace when it is killed - SAP ASE

Symptom

  • ASE reported an "infected with signal 11" error in the close_range__fdpr() call:

 Current process (0x15a0667) infected with signal 11 (SIGSEGV)
 Address 0x00000001003f5904 (close_range__fdpr_2+0xb4), siginfo (code, address) = (50, 0x00000000deadbb8e)

  • The error was followed by a stack trace. The stack trace included the following functions:

     close_range__fdpr_2()
     s_cleanframe()
     clean_process()
     kill_proc__fdpr_2()
     terminate_process()
     quitfn+0x44()
     s_execute__fdpr_119()
     sequencer()
     LeExecSqlFuncMain()
     LeExecSqlFunc()
    ...

Read more...

Environment

SAP Adaptive Server Enterprise (ASE)  15.x any release

Product

SAP Adaptive Server Enterprise 15.7 ; Sybase Adaptive Server Enterprise 15.0 ; Sybase Adaptive Server Enterprise 15.5

Keywords

CR688481, CR#688481, 688481, user-defined, function, session, killed, terminated , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.