2081789 - Netezza 7.0 Reverse Engineer is not supported – SAP PD 16.5 | SAP Knowledge Base Article

SAP Knowledge Base Article - Preview

2081789 - Netezza 7.0 Reverse Engineer is not supported – SAP PD 16.5

Symptom

  • PowerDesigner 16.5 SP04 and older releases do not support Netezza 7.0.
  • Users selects Netezza 5.0 DBMS to reverse Netezza 7.0 objects.
  • Views are not reversed: the Database Reverse Engineering dialog does not display any view.
  • The query executed by PowerDesigner to reverse Netezza 5.0 views returns an error when a Netezza 7.0 database is targeted:

ERROR: Unable to identify an operator '/=/' for types 'NAME' and 'NAME'

You will have to retype this query using an explicit cast.


Read more...

Environment

  • SAP PowerDesigner (PD) 16.5
  • SAP PowerDesigner (PD) 16.5 SP04
  • Netezza 7.0 DBMS

Product

SAP PowerDesigner 16.5 ; Sybase PowerAMC 16.5

Keywords

KBA , BC-SYB-PD-AMC , Power AMC , Product Enhancement

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required).