1845121 - Address already in use - how to find the process listening on port ... | SAP Knowledge Base Article

SAP Knowledge Base Article - Preview

1845121 - Address already in use - how to find the process listening on port ...

Symptom

SAP Message Server, Dispatcher, Gateway, WebDispatcher, ICM etc. does not start.
The corresponding traces dev_ms, dev_disp, dev_rd, dev_webdisp, dev_icm etc. write similar messages as shown below:

Windows:

***LOG Q0I=> NiIBindSocket: bind (10013: WSAEACCES: Permission denied)
[Thr 8548] *** ERROR => NiIBindSocket: SiBind failed for hdl 1 / sock 9
(SI_EPORT_INUSE/10013; I4; ST; 0.0.0.0:3600)
*** ERROR => MsSCommInit: NiBufListen(3600) (rc=NIESERV_USED)

Linux:


NiIBindSocket: bind (98: Address already in use)
*** ERROR => NiIBindSocket: SiBind failed for hdl 1 / sock 9
(SI_EPORT_INUSE/98; I4; ST; 0.0.0.0:3600)
*** ERROR => MsSCommInit: NiBufListen(3600) (rc=NIESERV_USED)

AIX:

NiIBindSocket: bind (67: Address already in use)
*** ERROR => NiIBindSocket: SiBind failed for hdl 1 / sock 9
(SI_EPORT_INUSE/67; I4; ST; 0.0.0.0:3600)
*** ERROR => MsSCommInit: NiBufListen(3600) (rc=NIESERV_USED)

HP-UX:

NiIBindSocket: bind (226: Address already in use)
*** ERROR => NiIBindSocket: SiBind failed for hdl 1 / sock 9
(SI_EPORT_INUSE/226; I4; ST; 0.0.0.0:3600)
*** ERROR => MsSCommInit: NiBufListen(3600) (rc=NIESERV_USED)

Solaris:

NiIBindSocket: bind (125: Address already in use)
*** ERROR => NiIBindSocket: SiBind failed for hdl 1 / sock 9
(SI_EPORT_INUSE/125; I4; ST; 0.0.0.0:3600)
*** ERROR => MsSCommInit: NiBufListen(3600) (rc=NIESERV_USED)

SAP Hana Database cannot be started. The Daemon trace contains lines like:

[115220]{-1} Network TrexHDB DaemonDaemon.cpp(02186) : cannot bind socket to 127.0.0.1:12345: Address already in use (98)
[115220]{-1} Network TrexDaemon.cpp(02192) : cannot listen on socket to 127.0.0.1:12345: Address already in use (98)


Read more...

Product

SAP NetWeaver all versions

Keywords

NiPBind:, icmbnd, ListenerThread:Init: unable to listen, IcmBindService: NiBuf2Listen failed, MsHttpCommInit, MsHttpPortBind:, DpCommInit: NiBufListen, GwInitService: NiDgBind , KBA , BC-NET , Network Infrastructure , BC-OP-NT , Windows , BC-OP-AIX , IBM AIX , BC-OP-LNX , Linux , BC-OP-HPX , HP-UX , BC-OP-SUN , SUN Solaris , BC-FES-IGS , Internet Graphics Server , BC-CST , Client/Server Technology , Problem

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.