SAP Knowledge Base Article - Preview

3001988 - Dropping Warm Standby standby connection crashes repserver - SRS

Symptom

  • Large backlog in logical inbound queue
  • While dropping the Standby database connection, encounter the following stacktrace in SRS errorlog:

    Thread USER(sa) infected with signal 10.
    exc__appDumpStack ()
    exc_terminate ()
    sun_svr4_catch_signal ()
    sqm_update_trunc_cnt ()
    _ddl_drop_db ()
    _ddl_db ()
    ddl_exec_cmd ()
    ddl_exec_cmd_wrapper ()
    _ex_process_cmds ()
    _ex_process_lang ()
    ex_lang_handler ()
    srv__exechandler ()
    srv__runclient ()
    srv__connhandle ()
    srv__start_function ()
    _thr_slot_offset ()

Image/data in this KBA is from SAP internal systems, sample data, or demo systems. Any resemblance to real data is purely coincidental.


Read more...

Environment

  • SAP Replication Server (SRS) 15.7.1
  • SAP Replication Server (SRS) 16.0
  • SAP Adaptive Server Enterprise (ASE) All versions

Product

SAP Adaptive Server Enterprise all versions ; SAP Replication Server 15.7 ; SAP Replication Server 16.0 ; SAP Sybase Replication Server 15.7, heterogeneous edition ; SAP Sybase Replication Server 15.7, option for IBM DB2 ; SAP Sybase Replication Server 15.7, option for Microsoft SQL Server ; SAP Sybase Replication Server 15.7, option for Oracle ; SAP Sybase Replication Server 15.7, real-time loading edition

Keywords

CR732154, CR#732154, 732154, RepServer, RS, stacktrace, crash, resynch , KBA , BC-SYB-REP , Sybase Replication Server (standalone) , Bug Filed

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.