SAP Knowledge Base Article - Preview

2962144 - Signal 11 in sparclock with ra_ci_stpmgr_thread in stack when execute 'sap_teardown' - SAP ASE

Symptom

  • When issue sap_teardown in HADR setup, ASE errorlog reports an Infected with Signal 11 (SIGSEGV) error in the module sparclock with a stack trace that contains at least one of the following functions:

ra_ci_stpmgr_thread
ra__ci_stpmgr_execute

  • Prior to signal 11, the following messages also reported in the ASE errorlog;

    Rep Agent on database 'db1' switched from mode 'sync' to mode 'async' because of a shutdown.
    kernel (CI-Info) Message: 76050, Severity: 0 Producer of Stream 'db1' is exiting.


Read more...

Environment

SAP Adaptive Server Enterprise (ASE) 16.0 SP03
HADR

Product

SAP Adaptive Server Enterprise 16.0

Keywords

sap_teardown, spinlock, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, registers , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed