2668808 - token datastream length not correct; signal 11 in tdsrecv__xoltp_setup() - SAP ASE

Symptom

  • SAP NetWeaver JAVA applications or custom JAVA applications fail with an SAP ASE database error : 

    "The token datastream length was not correct. This is an internal protocol error. Command has been aborted."

  • A corresponding "infected with signal 11" error in the module tdsrecv__xoltp_setup() is seen in the ASE errorlog, followed by a stack trace:

Current process (0x46f0238) infected with signal 11 (SIGSEGV)
Address 0x0x00000000008ac8c4 (tdsrecv__xoltp_setup+0xd2)

  • The stack trace includes modules:

tdsrecv__xoltp_setup
tdsrecv__dynexec_xoltp
tdsrecv__dynexec
tdsrecv_dynamic

  Note: A complete stack trace is available under Attachments.

  • The stack traces also shows a last encountered error as Error 3805:

lasterror = 3805

  • The text for Error 3805 is: "The token datastream length was not correct. This is an internal protocol error. Command has been aborted."


Read more...

Environment

  • SAP Adaptive Server Enterprise (ASE) 16.0 for Business Suite
  • SAP Adaptive Server Enterprise (ASE) 16.0 
  • SAP Adaptive Server Enterprise (ASE) 15.7 

Product

SAP Adaptive Server Enterprise 15.7 ; SAP Adaptive Server Enterprise 16.0 ; SAP NetWeaver 7.5

Keywords

CR816111, 818953, CR818953, 816111, token, datastream, length, JAVA, 3805, tdsrecv__xoltp_setup , KBA , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed