SAP Knowledge Base Article - Preview

2614684 - Introscope EM does not start due to wrong ELF data format

Symptom

  • Introscope 10.5\10.7 is successfully installed on Solaris OS but after installation the EM does not start.
  • The error found in Introscope logs is the following:
3/06/18 11:59:47.229 AM MET [INFO] [main] [Manager.ServerSocketFactory] Created Server Socket Factory: com.wily.jip.server.ext.DefaultServerSocketFactory
3/06/18 11:59:47.337 AM MET [ERROR] [main] [Manager] The EM failed to start. /var/tmp/librocksdbjni8441345954209439860.so: ld.so.1: java: fatal: /var/tmp/librocksdbjni8441345954209439860.so: wrong ELF data format: ELFDATA2MSB (Possible cause: endianness mismatch)
3/06/18 11:59:47.350 AM MET [INFO] [main] [Manager] Shutting down the Isengard server


Read more...

Environment

  • SAP Solution Manager
  • Introscope Enterprise Manager 10.5 and 10.7
  • Solaris OS

Product

SAP Solution Manager 7.1 ; SAP Solution Manager 7.2

Keywords

wily, Solaris 11, Introscope compatibility , KBA , XX-PART-WILY , Introscope by CA Technologies , Problem

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.