Symptom

When running a query using 'set show_transformed_sql on', the following "infected with signal 11" errors may happen:

  • Current process (0xcd0067) infected with signal 11 (SIGSEGV)
    Address 0x0x00000000013950ac (OmniQuickPass::locateSubquery(tree*, tree**)+0x3a), siginfo (code, address) = (1, 0x0x0000003800000018)
     
    This error is followed by a stack trace that includes functions:

OmniQuickPass::locateSubquery
OmniQuickPass::locateOjRange
OmniQuickPass::handleOJBlock
OmniQuickPass::buildAnsiFrom
OmniQuickPass::generateSelect
OmniQuickPass::generateStatement
LeSQLRep::LeSQLRep
CgGenLava::CGConsDMLOp
CgpInsert::_cgpCodeGen
CgpPop::cgpCodeGen
CgpPop::prepareCodeGenCgp
CgpEmit::_cgpCodeGen
CgpPop::cgpCodeGen
GenLava
s_compile_stmt
s_compile
sequence
internal_sql
s_runtime_compile
s_execute

  • Current process (0x850043) infected with signal 11 (SIGSEGV)
    Address 0x0x000000000139e446 (OmniQuickPass::expandRangetableName(range*, int, bool, int)+0x52), siginfo (code, address) = (1, 0x0x0000000000000138)
     
    This error is followed by a stack trace that includes functions:Other stack trace that can be reported:

OmniQuickPass::expandRangetableName
OmniQuickPass::generateResvar
OmniQuickPass::generateDelete
OmniQuickPass::generateStatement
generateTransSQL
s_preprocess
s_compile

  • Current process (0xeb0076) infected with signal 11 (SIGSEGV)                                                                              
    Address 0x0x0000000001fc7724 (OmniQuickPass::varExpression(tree*, tree*, tree*)+0x1a4), siginfo (code, address) = (1, 0x0x0000000000000008)
     
    This error is followed by a stack trace that includes functions:

OmniQuickPass::varExpression
OmniQuickPass::generateExpression
OmniQuickPass::genClause
OmniQuickPass::generateWhere
OmniQuickPass::generateSelect
OmniQuickPass::generateExpression
OmniQuickPass::genClause
OmniQuickPass::generateWhere
OmniQuickPass::generateSelect
OmniQuickPass::generateUnion
OmniQuickPass::generateStatement
generateTransSQL
s_preprocess
s_compile

Note: Complete stack traces are available under Attachments.


Read more...

Environment

  • SAP Adaptive Server Enterprise (ASE) 15.7 SP138 
  • SAP Adaptive Server Enterprise (ASE) 16.0 SP02 PL07

Product

SAP Adaptive Server Enterprise 15.7 ; SAP Adaptive Server Enterprise 16.0

Keywords

CR#813292, CR813292, 813292, CR#813359, CR813359, 813359, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace,  stack, registers, proxy, join, outer, subquery , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , Bug Filed

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.