SAP Knowledge Base Article - Preview

2574170 - Signal 11 in altdb__report_shrinklog_info() - SAP ASE

Symptom

  • When running the ALTER DATABASE ... OFF command
  • An "infected with signal 11" error in the module altdb__clear_chunk() followed by a stack trace is reported in the ASE errorlog:

Current process (0x4f0028) infected with signal 11 (SIGSEGV)
Address 0x0x0000000000f3f1ac (altdb__clear_chunk+0x5cc), siginfo (code, address) = (1, 0x0x0000000000000005)

  • The stack trace includes functions:

altdb__clear_chunk
altdb__clear_lpages
altdb__do_shrinkdb
altdb_shrink
alterdb

  Note: A complete stack trace is available under Attachments.


Read more...

Environment

  • SAP Adaptive Server Enterprise (ASE) 15.7
  • SAP Adaptive Server Enterprise (ASE) 16.0

Product

SAP Adaptive Server Enterprise 15.7 ; SAP Adaptive Server Enterprise 16.0

Keywords

CR807128, CR#807128, 807128, SEGV, segmentation, storage, access, violation, fault, segfault, kisignal, stacktrace, registers, shrink , KBA , BC-SYB-ASE , Sybase ASE Database Platform (non Business Suite) , BC-DB-SYB , Business Suite on Adaptive Server Enterprise , Bug Filed

About this page

This is a preview of a SAP Knowledge Base Article. Click more to access the full version on SAP ONE Support launchpad (Login required).

Search for additional results

Visit SAP Support Portal's SAP Notes and KBA Search.