Symptom
-
Job SM:SELFDIAGNOSIS ends with Internal session terminated with the following runtime error (see ST22):
"Category ABAP Programming Error
Runtime Errors SYNTAX_ERROR
ABAP Program CL_DWSP_SD_CONNECTIONS========CP
Application Component SV-SMG-SDG
The current ABAP program "CL_DSWP_SD_MODEL_ALERT_DEF====CP" had to be
terminated because it has
come across a statement that unfortunately cannot be executed.
The following syntax error occurred in program
"CL_DWSP_SD_CONNECTIONS========CP " in include
"CL_DWSP_SD_CONNECTIONS========CM006 " in
line 477:
"Incorrect nesting: For the statement "CATCH", there is no open structu"
"re introduced by "TRY".
In the source code you have the termination point in line 11
of the (Include) program "CL_DSWP_SD_MODEL_ALERT_DEF====CM00E".
The program "CL_DSWP_SD_MODEL_ALERT_DEF====CP" was started as a background job. " - Source code extract -IF lv_class_name IS INITIAL. | 7| RETURN. | 8| ENDIF. | 9| | 10| TRY . |>>>>>| CREATE OBJECT result | 12| TYPE
Read more...
Environment
SAP Solution Manager 7.1 SP10 SP11 and SP12
Product
Keywords
SM:SELFDIAGNOSIS, CL_DWSP_SD_CONNECTIONS,Incorrect nesting, SNOTE. , KBA , SV-SMG-SDG , Self Diagnosis for SAP Solution Manager , BC-UPG-NA , SAP Notes Assistant , Problem