Symptom
- Connection server fails to start
- Web Intelligence Processing server fails to start
- Connection server and Web Intelligence Processing server fail: This server is considered failed because it has stopped 5 time(s) in 60 minute(s)
- Connection server and Web Intelligence Processing server keep at Starting or Failed status
- /var/log/messages show the below error relating to the Web Intelligence Processing Server stopping:
"the root server reported an error Unknown." - When opening WebI Rich Client from BI Launch Pad, the following error message pops up: "your session timed out. Close the Java interface and log on again."
### Extract from connectionserver logs:
|8a6384ea-470c-849f-801b-52a9a61de2c8|2012 01 28 10:17:02:832|+0200|>>|A| |connectionserver_boserver.ConnectionServer|10481|1028091800|| ||||||||||||||||||||||assert failure: (oscafactory2.cpp:3129). (false : OSCASimpleFactory2::triggerStateChangeNotifications - Unexpected exception).
### Extract from the stack trace:
#4 0x00002b70a3165086 in Ocalibhelper500::OSCASimpleFactory2::triggerStateChangeNotifications(Ocalibhelper500::CWireObject const*) ()
from /opt/sap/BI4/sap_bobj/enterprise_xi40/linux_x64/libOCAhelperw.so
#5 0x00000000005da387 in CISGeneralAdmin_impl::setParamEx(unsigned short const*, CORBA_Any const&, CORBA_Any*&) ()
Read more...
Environment
- SAP BusinessObjects Business Intelligence Platform (BI) 4.0 SP01 Patch 6 - BI 4.0 SP02 Patch 10
- SAP BusinessObjects Business Intelligence Platform (BI) 4.1 SP02 Patch 1
- Linux Red Hat 5.5, 5.6
- AIX
- Linux Suse Enterprise